A quick-lube shop adds refrigerant to customers' A/C systems at no extra charge as part of a paid service package. Does the person doing this need Section 609 certification?
- No, because the customer is not charged for the refrigerant
- Yes, because the work is part of a service the customer pays for
- No, because adding refrigerant is not considered service
- Yes, but only if more than one full pound of refrigerant is added
Show the answer
B. Yes, because the work is part of a service the customer pays for
Service 'for consideration' includes work bundled into a paid visit, even if the top-off itself is listed as free. Adding refrigerant is servicing the system, and there is no minimum quantity.
Reference: 40 CFR 82.32 (service for consideration); 82.34
A car owner recharges the A/C on their own car at home. Which statement is correct under federal rules?
- No certification is needed, but venting is still illegal
- Certification is needed because any refrigerant work requires it
- No certification is needed, and venting small amounts is allowed
- Certification is needed only if the car uses R-1234yf
Show the answer
A. No certification is needed, but venting is still illegal
Section 609 certification applies to service for payment, so a do-it-yourselfer is not covered. The venting prohibition, however, applies to everyone.
Reference: 40 CFR 82.34; Clean Air Act Section 608(c)
How often must a Section 609 certification be renewed?
- Every 2 years
- Every 5 years
- Whenever a new refrigerant is introduced
- Never; it does not expire
Show the answer
D. Never; it does not expire
Section 609 certification is good for life. Updated training on newer refrigerants such as R-1234yf is strongly recommended but is not a federal renewal requirement.
Reference: 40 CFR 82.40