SAE J2788 is the standard for equipment that recovers, recycles and recharges
- R-12
- R-1234yf
- R-134a
- R-744
Show the answer
C. R-134a
J2788 covers R-134a recovery/recycling/recharging machines. R-1234yf machines are built to J2843, and the old R-12 machines to J1990.
Reference: SAE J2788; 40 CFR Part 82 Subpart B, Appendix C
SAE J2843 is the standard for equipment that recovers, recycles and recharges
- R-134a
- R-12
- R-152a
- R-1234yf
Show the answer
D. R-1234yf
J2843 covers machines for R-1234yf and includes design features for a mildly flammable refrigerant. J2788 is the R-134a counterpart.
Reference: SAE J2843; 40 CFR Part 82 Subpart B
A recovery/recycling/recharging machine built to SAE J2788 must be able to recover at least what share of the refrigerant in the system?
- 70 percent
- 80 percent
- 95 percent
- 100 percent
Show the answer
C. 95 percent
J2788 raised the bar to 95 percent recovery, because older machines often left a large part of the charge in the system. No machine can guarantee 100 percent.
Reference: SAE J2788