SAE J2788 is the standard for equipment that recovers, recycles and recharges
- R-12
- R-1234yf
- R-134a
- R-744
Show the answer
C. R-134a
J2788 covers R-134a recovery/recycling/recharging machines. R-1234yf machines are built to J2843, and the old R-12 machines to J1990.
Reference: SAE J2788; 40 CFR Part 82 Subpart B, Appendix C
What is the ASHRAE safety classification of R-1234yf?
- A1
- A2L
- A3
- B2L
Show the answer
B. A2L
R-1234yf is A2L: lower toxicity (A) and lower flammability (2L). A1 is non-flammable, like R-134a, and A3 is highly flammable, like propane.
Reference: ASHRAE Standard 34
A quick-lube shop adds refrigerant to customers' A/C systems at no extra charge as part of a paid service package. Does the person doing this need Section 609 certification?
- No, because the customer is not charged for the refrigerant
- Yes, because the work is part of a service the customer pays for
- No, because adding refrigerant is not considered service
- Yes, but only if more than one full pound of refrigerant is added
Show the answer
B. Yes, because the work is part of a service the customer pays for
Service 'for consideration' includes work bundled into a paid visit, even if the top-off itself is listed as free. Adding refrigerant is servicing the system, and there is no minimum quantity.
Reference: 40 CFR 82.32 (service for consideration); 82.34