EPA 608 Practice Test: Core, Type I, II and III

Every section of the EPA Section 608 technician certification: Core, Type I (small appliances), Type II (high pressure) and Type III (low pressure).

180 questions · 4 topics · free, no sign-up

Beta. These questions are new and are being checked by licensed tradespeople. If one looks wrong, use “Report this question” and we will fix it.

Mixed practice test

10 questions, graded as you go, with the reason for every answer. No sign-up.

Timed mock exam

50 questions in 60 minutes, drawn from every topic. No answers shown until the end, then a score, your weakest topics and a review of what you missed.

Practise by topic

Sample questions

Why do HCFCs do less damage to the ozone layer than CFCs?

  1. The hydrogen in the molecule lets it break down lower in the atmosphere
  2. The fluorine in the molecule cancels out the effect of the chlorine atoms
  3. HCFC molecules are too heavy to rise above the troposphere
  4. HCFC molecules contain bromine in place of the chlorine
Show the answer

A. The hydrogen in the molecule lets it break down lower in the atmosphere

Hydrogen makes an HCFC molecule less stable, so most of it breaks down before reaching the stratosphere and less chlorine arrives there. Fluorine does not neutralize chlorine, and molecular weight does not keep refrigerants out of the stratosphere.

Reference: EPA Section 608 Core

A technician who holds only Type I certification is asked to recover the refrigerant from a 3-ton residential split system. The technician

  1. may do the work, because the charge is under 15 lb
  2. may do the work if a self-contained machine is used
  3. may not do the work, because it requires Type II certification
  4. may not do the work, because it requires Type III certification
Show the answer

C. may not do the work, because it requires Type II certification

A split system is not a small appliance, so Type I does not cover it; R-22 and R-410A split systems are high-pressure appliances under Type II. The size of the charge alone does not make something a small appliance.

Reference: 40 CFR 82.161

Type II certification covers which equipment?

  1. Low-pressure centrifugal chillers and the purge units that are fitted to them
  2. Factory-sealed appliances that hold five pounds of refrigerant or less
  3. Motor vehicle air conditioners and the MVAC-like systems on farm equipment
  4. Medium-, high- and very high-pressure appliances other than small appliances and MVACs
Show the answer

D. Medium-, high- and very high-pressure appliances other than small appliances and MVACs

Type II covers medium-, high- and very high-pressure appliances, except small appliances (Type I) and motor vehicle systems (Section 609). Low-pressure chillers fall under Type III.

Reference: 40 CFR 82.161

R-123 belongs to which group of refrigerants?

  1. HCFC
  2. CFC
  3. HFC
  4. HFO
Show the answer

A. HCFC

R-123 is an HCFC that replaced CFC-11 in low-pressure chillers. Because it still contains chlorine it has a small ODP and is covered by the Section 608 leak repair rule.

Reference: Clean Air Act Title VI (Class II substances)

Chlorine from CFCs reaches the stratosphere, while most chlorine from natural sources such as sea spray does not. What is the main reason?

  1. CFCs are lighter than air, so they rise much faster than natural chlorine does
  2. CFCs are released at high altitude, well above the clouds and the rain
  3. CFCs are stable and do not dissolve in water, so rain does not wash them out
  4. CFCs carry far more chlorine per molecule than any natural source does
Show the answer

C. CFCs are stable and do not dissolve in water, so rain does not wash them out

CFCs do not break down or dissolve in water in the lower atmosphere, so they survive long enough to drift up to the stratosphere. Natural chlorine compounds are water soluble and are rained out. CFCs are actually heavier than air; mixing by winds carries them up.

Reference: EPA Section 608 Core